Single Core Cables, with Stranded Circular Copper Conductors, XLPE Insulated and PVC Sheathed. 0.6/1 (1.2) kV
- Soft annealed stranded copper conductor, insulated with an XLPE compound covered with a layer of PVC compound to form the overall jacket.
- Cables are produced according to IEC 60502-1 and BS 7889.
.
Summary of cables specifications
CT10X101U2 |
Single Core |
Copper |
XLPE |
10 | 1.83 | - | 2.33 | 107 | 94 | 74 | 92 | 87 | 75 | 8.3 | 150 |
PVC |
Unarmored |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CT11X101U2 |
Single Core |
Copper |
XLPE |
16 | 1.15 | - | 1.47 | 126 | 121 | 95 | 128 | 121 | 105 | 9.3 | 210 |
PVC |
Unarmored |
CT12X101U2 |
Single Core |
Copper |
XLPE |
25 | 0.727 | - | 0.927 | 164 | 155 | 120 | 157 | 151 | 133 | 11 | 315 |
PVC |
Unarmored |
CT13X101U2 |
Single Core |
Copper |
XLPE |
35 | 0.524 | - | 0.669 | 195 | 187 | 149 | 197 | 190 | 167 | 12.1 | 410 |
PVC |
Unarmored |
CT14X101U2 |
Single Core |
Copper |
XLPE |
50 | 0.387 | - | 0.494 | 229 | 218 | 178 | 243 | 231 | 202 | 13.8 | 555 |
PVC |
Unarmored |
CT15X101U2 |
Single Core |
Copper |
XLPE |
70 | 0.268 | - | 0.343 | 287 | 269 | 218 | 306 | 295 | 260 | 15.7 | 760 |
PVC |
Unarmored |
CT16X101U2 |
Single Core |
Copper |
XLPE |
95 | 0.193 | - | 0.248 | 338 | 320 | 264 | 382 | 370 | 318 | 17.7 | 1015 |
PVC |
Unarmored |
CT17X101U2 |
Single Core |
Copper |
XLPE |
120 | 0.153 | - | 0.197 | 389 | 366 | 298 | 444 | 433 | 375 | 19.6 | 1280 |
PVC |
Unarmored |
CT18X101U2 |
Single Core |
Copper |
XLPE |
150 | 0.124 | - | 0.16 | 429 | 407 | 338 | 503 | 491 | 42B | 21.8 | 1570 |
PVC |
Unarmored |
CT19X101U2 |
Single Core |
Copper |
XLPE |
185 | 0.0991 | - | 0.129 | 493 | 463 | 384 | 583 | 572 | 485 | 23.9 | 1920 |
PVC |
Unarmored |
CT20X101U2 |
Single Core |
Copper |
XLPE |
240 | 0.0754 | - | 0.099 | 567 | 532 | 440 | 716 | 705 | 590 | 27.1 | 2530 |
PVC |
Unarmored |
CT30X101U2 |
Single Core |
Copper |
XLPE |
300 | 0.0601 | - | 0.081 | 641 | 595 | 498 | 906 | 832 | 682 | 29.7 | 3105 |
PVC |
Unarmored |
CT40X101U2 |
Single Core |
Copper |
XLPE |
400 | 0.047 | - | 0.0638 | 732 | 676 | 561 | 982 | 959 | 785 | 33.9 | 4135 |
PVC |
Unarmored |
CT50X101U2 |
Single Core |
Copper |
XLPE |
500 | 0.0366 | - | 0.0517 | 829 | 755 | 623 | 1109 | 1086 | 895 | 37.4 | 5110 |
PVC |
Unarmored |
CT60X101U2 |
Single Core |
Copper |
XLPE |
630 | 0.0283 | - | 0.0425 | 950 | 847 | 710 | 1271 | 1247 | 1052 | 41.9 | 6455 |
PVC |
Unarmored |
CT70X101U2 |
Single Core |
Copper |
XLPE |
800 | 0.0221 | - | 0.0292 | 1043 | 938 | 801 | 1444 | 1421 | 1201 | 46.8 | 8260 |
PVC |
Unarmored |
• For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in |
urban networks, industrial plants, as well as in thermopower and hydropower stations. |
- IEC 60502-1