Multicore Cables, with Stranded Circular Copper Conductors, XLPE Insulated, Armored by Steel Wires and LSHF Sheathed. 0.6/1 (1.2) KV

 

  • Multicore cables of the stranded copper conductors are insulated with an XLPE compound, assembled, armored with steel wires, and covered with an overall jacket of an LSHF compound.

 

  • Cables are produced according to IEC 60502-1 & BS 6724.

.

Summary of cables specifications
CT12X102WL Two Core Cables
Copper
XLPE
25 r 0.727 --- 0.927 153 118 154 24.1 1410 LSHF
SWA
CT13X102WL Two Core Cables
Copper
XLPE
35 r 0.524 --- 0.669 183 147 185 26.3 1715 LSHF
SWA
CT12X103WL Three Core Cables
Copper
XLPE
25 r 0.727 --- 0.927 142 112 132 25.8 1620 LSHF
SWA
CT13X103WL Three Core Cables
Copper
XLPE
35 r 0.524 --- 0.669 172 133 162 28.2 1990 LSHF
SWA
CT12X104WL Four Core Cables
Copper
XLPE
25 r 0.727 --- 0.927 142 112 134 27.8 1975 LSHF
SWA
CT13X104WL Four Core Cables
Copper
XLPE
35 r 0.524 --- 0.669 172 133 162 30.7 2465 LSHF
SWA
CT14X104WL Four Core Cables
Copper
XLPE
50 s 0.387 --- 0.494 202 158 202 33.1 3200 LSHF
SWA
CT15X104WL Four Core Cables
Copper
XLPE
70 s 0.268 --- 0.343 240 196 242 39.2 4645 LSHF
SWA
CT16X104WL Four Core Cables
Copper
XLPE
95 s 0.193 --- 0.248 289 229 300 42.9 5870 LSHF
SWA
CT17X104WL Four Core Cables
Copper
XLPE
120 s 0.153 --- 0.197 332 267 347 48.4 7555 LSHF
SWA
CT18X104WL Four Core Cables
Copper
XLPE
150 s 0.124 --- 0.16 365 300 413 53.1 8985 LSHF
SWA
CT19X104WL Four Core Cables
Copper
XLPE
185 s 0.0991 --- 0.129 409 338 451 57.9 10760 LSHF
SWA
CT20X104WL Four Core Cables
Copper
XLPE
240 s 0.0754 --- 0.099 474 398 537 64.1 13480 LSHF
SWA
CT30X104WL Four Core Cables
Copper
XLPE
300 s 0.0601 --- 0.081 534 441 618 69.7 16215 LSHF
SWA
CT40X104WL Four Core Cables
Copper
XLPE
400 s 0.047 --- 0.0642 596 500 697 76.8 20190 LSHF
SWA
CT13X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
35 sm + 16 rm 0.5240/1.1500 --- 0.6690/1.4700 172 133 162 28.9 2210 LSHF
SWA
CT14X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
50 sm + 25 rm 0.3870/0.7270 --- 0.4940/0.9270 202 158 202 31.3 2860 LSHF
SWA
CT15X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
70 sm + 35 rm 0.2680/0.5240 --- 0.3430/0.6690 240 196 242 37.5 4240 LSHF
SWA
CT16X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
95 sm + 50 sm 0.1930/0.3870 --- 0.2480/0.4940 289 229 300 41.2 5290 LSHF
SWA
CT17X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
120 sm + 70 sm 0.1530/0.2680 --- 0.1970/0.3430 332 267 347 45.3 6475 LSHF
SWA
CT18X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
150 sm + 70 sm 0.1240/0.2680 --- 0.1600/0.3430 365 300 413 50.5 8055 LSHF
SWA
CT19X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
185 sm + 95 sm 0.0991/0.1930 --- 0.1290/0.2480 409 338 451 55.4 9735 LSHF
SWA
CT20X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
240 sm + 120 sm 0.0754/0.1530 --- 0.0990/0.1970 474 398 537 60.3 11780 LSHF
SWA
CT30X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
300 sm + 150 sm 0.0601/0.1240 --- 0.0810/0.1600 534 441 618 66.4 14435 LSHF
SWA
CT40X105WL Four Core Cables with Reduced Neutral
Copper
XLPE
400 sm + 240 sm 0.0470/0.0754 --- 0.0642/0.099 596 500 697 72.7 18500 LSHF
SWA
  • For outdoor installations in damp wet locations where mechanical damages are expected to occur.
  • IEC 60502-1
  • BS 6724

Download the full specifications PDF for more info
SPECS PDF